MammaGutt wrote:
Do showpd -i
I'm pretty sure there was a replacement at one point that didn't remove the old pd id on exit.
Output bellow:
LAV-3PAR cli% showpd -i
Id CagePos State ----Node_WWN---- -MFR- -----Model------ -Serial- -FW_Rev- Protocol MediaType -----AdmissionTime-----
0 0:0:0 normal 5000CCA05952B043 HGST HKCF0600S5xeN015 0XHGGS6P 3P02 SAS Magnetic 2016-01-22 09:48:49 EST
1 0:1:0 normal 5000CCA059529C3B HGST HKCF0600S5xeN015 0XHGEDVP 3P02 SAS Magnetic 2016-01-22 09:48:50 EST
2 0:2:0 normal 5000CCA059529C1F HGST HKCF0600S5xeN015 0XHGEDMP 3P02 SAS Magnetic 2016-01-22 09:48:50 EST
3 0:3:0 normal 5000CCA059529C6B HGST HKCF0600S5xeN015 0XHGEE7P 3P02 SAS Magnetic 2016-01-22 09:48:50 EST
4 0:4:0 normal 5000CCA05952B293 HGST HKCF0600S5xeN015 0XHGGWZP 3P02 SAS Magnetic 2016-01-22 09:48:51 EST
5 0:5:0 normal 5000CCA05952B027 HGST HKCF0600S5xeN015 0XHGGRZP 3P02 SAS Magnetic 2016-01-22 09:48:51 EST
6 0:6:0 normal 5000CCA059520693 HGST HKCF0600S5xeN015 0XHG3EWV 3P02 SAS Magnetic 2016-01-22 09:48:51 EST
7 0:7:0 normal 5000CCA05952CD8B HGST HKCF0600S5xeN015 0XHGJPNV 3P02 SAS Magnetic 2016-01-22 09:48:51 EST
8 0:8:0 normal 5000CCA059511C7F HGST HKCF0600S5xeN015 0XHELVMV 3P02 SAS Magnetic 2016-01-22 09:48:52 EST
9 0:9:0 normal 5000CCA059516E07 HGST HKCF0600S5xeN015 0XHET8YV 3P02 SAS Magnetic 2016-01-22 09:48:52 EST
10 0:10:0 normal 5000CCA05952E56B HGST HKCF0600S5xeN015 0XHGL8YP 3P02 SAS Magnetic 2016-01-22 09:48:52 EST
11 0:11:0 normal 5000CCA059534127 HGST HKCF0600S5xeN015 0XHGTDAP 3P02 SAS Magnetic 2016-01-22 09:48:53 EST
12 1:0:0 normal 5000CCA05952CC07 HGST HKCF0600S5xeN015 0XHGJLJP 3P02 SAS Magnetic 2016-01-22 09:48:53 EST
13 1:1:0 normal 5000CCA05952FC57 HGST HKCF0600S5xeN015 0XHGMU8P 3P02 SAS Magnetic 2016-01-22 09:48:53 EST
14 1:2:0 normal 5000CCA05952CBF3 HGST HKCF0600S5xeN015 0XHGJLBP 3P02 SAS Magnetic 2016-01-22 09:48:53 EST
15 1:3:0 normal 5000CCA05952FC6F HGST HKCF0600S5xeN015 0XHGMUGP 3P02 SAS Magnetic 2016-01-22 09:48:54 EST
16 1:4:0 normal 5000CCA05952F43F HGST HKCF0600S5xeN015 0XHGM8KP 3P02 SAS Magnetic 2016-01-22 09:48:54 EST
17 1:5:0 normal 5000CCA05952F473 HGST HKCF0600S5xeN015 0XHGM8ZP 3P02 SAS Magnetic 2016-01-22 09:48:54 EST
18 1:6:0 normal 5000CCA05952F46F HGST HKCF0600S5xeN015 0XHGM8YP 3P02 SAS Magnetic 2016-01-22 09:48:54 EST
19 1:7:0 normal 5000CCA059531D1B HGST HKCF0600S5xeN015 0XHGPZXP 3P02 SAS Magnetic 2016-01-22 09:48:55 EST
20 1:8:0 normal 5000CCA05952CADF HGST HKCF0600S5xeN015 0XHGJJ4P 3P02 SAS Magnetic 2016-01-22 09:48:55 EST
21 1:9:0 normal 5000CCA05952E4EB HGST HKCF0600S5xeN015 0XHGL7XP 3P02 SAS Magnetic 2016-01-22 09:48:55 EST
22 1:10:0 normal 5000CCA059534437 HGST HKCF0600S5xeN015 0XHGTLNP 3P02 SAS Magnetic 2016-01-22 09:48:56 EST
23 1:11:0? degraded 5000CCA05953442F HGST HKCF0600S5xeN015 0XHGTLLP 3P02 SAS Magnetic 2016-01-22 09:48:56 EST
24 1:11:0 normal 5000CCA0599935F3 HGST HKCF0600S5xeN015 0XJR82AP 3P02 SAS Magnetic 2018-03-06 10:36:41 EST
------------------------------------------------------------------------------------------------------------------------
25 total
LAV-3PAR cli%
I can see that by AdmissionTime colum, disk ID 24 is different (newer) than others so I guess that someone before me replace the PD, how do I remove disk ID 23 (the degraded) from the system or there is another operation to remove PD that state is degraded?