3par cli% showcage Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model FormFactor 0 cage0 0:1:1 0 1:1:1 0 22 19-24 4082 4082 DCN2 SFF 3par cli% showport N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState 0:0:1 target ready 2FF70002AC023E62 20010002AC023E62 host FC - 1:0:1 none 0:0:2 target ready 2FF70002AC023E62 20020002AC023E62 host FC - 1:0:2 none 0:1:1 initiator ready 50002ACFF7023E62 50002AC011023E62 disk SAS DP-1 - - 0:1:2 initiator loss_sync 50002ACFF7023E62 50002AC012023E62 free SAS DP-2 - - 0:3:1 peer offline - 9418824939C9 free IP IP0 - - 1:0:1 target ready 2FF70002AC023E62 21010002AC023E62 host FC - 0:0:1 none 1:0:2 target ready 2FF70002AC023E62 21020002AC023E62 host FC - 0:0:2 none 1:1:1 initiator ready 50002ACFF7023E62 50002AC111023E62 disk SAS DP-1 - - 1:1:2 initiator loss_sync 50002ACFF7023E62 50002AC112023E62 free SAS DP-2 - - 1:3:1 peer offline - 941882493FA1 free IP IP1 - - ------------------------------------------------------------------------------------------------------- 10 3par cli% checkhealth -detail Checking alert Checking ao Checking cabling Checking cage Checking cert Checking dar Checking date Checking file Checking fs Checking host Checking ld Checking license Checking network Checking node Checking pd Checking pdch Checking port Checking qos Checking rc Checking snmp Checking task Checking vlun Checking vv Checking sp Component ----Summary Description---- Qty License Licenses which have expired 1 ----------------------------------------- 1 total 1 Component -Identifier- -Detailed Description- License Peer Motion License has expired --------------------------------------------- 1 total 3par cli% cgcmd -tc tty -C cage0 -c report_faults -p b ---------------------------------------------------------------------- Canister Manager faults Canister 0 Faults: 12 component(s) registered with fault tracker 0: I2C 0: No faults 1: I2C 1: No faults 2: I2C 2: No faults 3: I2C 3: No faults 4: I2C 4: No faults 5: I2C 5: No faults 6: Midplane VPD 0: No faults 7: PCM VPD 0: No faults 8: PCM VPD 1: No faults 9: Canister VPD 0: No faults 10: SGPIO 0: No faults 11: Canister CPLD 0: No faults Canister 1 Faults: 12 component(s) registered with fault tracker 0: I2C 0: No faults 1: I2C 1: No faults 2: I2C 2: No faults 3: I2C 3: No faults 4: I2C 4: No faults 5: I2C 5: No faults 6: Midplane VPD 0: No faults 7: PCM VPD 0: No faults 8: PCM VPD 1: No faults 9: Canister VPD 0: No faults 10: SGPIO 0: No faults 11: Canister CPLD 0: No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Cable Manager faults Overall cable status ----------------------------------------------------------------------- Index | Fault Severity | Fault LED State | Ident LED State ----------------------------------------------------------------------- Local ----------------------------------------------------------------------- 0 | OK | OFF | OFF 1 | OK | OFF | OFF 2 | Cable Removed | OFF | OFF ----------------------------------------------------------------------- Remote ----------------------------------------------------------------------- 0 | OK | OFF | OFF 1 | OK | OFF | OFF 2 | Cable Removed | OFF | OFF ----------------------------------------------------------------------- Detected local fault conditions ------------------------------ Cable 0 faults: No faults detected Cable 1 faults: No faults detected Cable 2 faults: No faults detected Detected remote fault conditions ------------------------------ Cable 0 faults: No faults detected Cable 1 faults: No faults detected Cable 2 faults: No faults detected ---------------------------------------------------------------------- ---------------------------------------------------------------------- Drive Manager faults No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Environmental Control faults No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Expander Manager faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Human Interface Device faults Ops Panel status: Unit Identifier LED : OFF Logic Fault LED : OFF Module Fault LED : OFF Warning: Local: Remote: ****No HID warnings to report**** No alarms to report RemoteSync Client faults No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Power Manager faults No faults ---------------------------------------------------------------------- 3par cli% cgcmd -tc tty -C cage0 -c report_faults -p a ---------------------------------------------------------------------- Canister Manager faults Canister 0 Faults: 12 component(s) registered with fault tracker 0: I2C 0: No faults 1: I2C 1: No faults 2: I2C 2: No faults 3: I2C 3: No faults 4: I2C 4: No faults 5: I2C 5: No faults 6: Midplane VPD 0: No faults 7: PCM VPD 0: No faults 8: PCM VPD 1: No faults 9: Canister VPD 0: No faults 10: SGPIO 0: No faults 11: Canister CPLD 0: No faults Canister 1 Faults: 12 component(s) registered with fault tracker 0: I2C 0: No faults 1: I2C 1: No faults 2: I2C 2: No faults 3: I2C 3: No faults 4: I2C 4: No faults 5: I2C 5: No faults 6: Midplane VPD 0: No faults 7: PCM VPD 0: No faults 8: PCM VPD 1: No faults 9: Canister VPD 0: No faults 10: SGPIO 0: No faults 11: Canister CPLD 0: No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Cable Manager faults Overall cable status ----------------------------------------------------------------------- Index | Fault Severity | Fault LED State | Ident LED State ----------------------------------------------------------------------- Local ----------------------------------------------------------------------- 0 | OK | OFF | OFF 1 | OK | OFF | OFF 2 | Cable Removed | OFF | OFF ----------------------------------------------------------------------- Remote ----------------------------------------------------------------------- 0 | OK | OFF | OFF 1 | OK | OFF | OFF 2 | Cable Removed | OFF | OFF ----------------------------------------------------------------------- Detected local fault conditions ------------------------------ Cable 0 faults: No faults detected Cable 1 faults: No faults detected Cable 2 faults: No faults detected Detected remote fault conditions ------------------------------ Cable 0 faults: No faults detected Cable 1 faults: No faults detected Cable 2 faults: No faults detected ---------------------------------------------------------------------- ---------------------------------------------------------------------- Drive Manager faults No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Environmental Control faults No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Expander Manager faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Human Interface Device faults Ops Panel status: Unit Identifier LED : OFF Logic Fault LED : OFF Module Fault LED : OFF Warning: Local: Remote: ****No HID warnings to report**** No alarms to report RemoteSync Client faults No faults ---------------------------------------------------------------------- ---------------------------------------------------------------------- Power Manager faults No faults 3par cli% shownode Control Data Cache Node ----Name---- -State- Master InCluster -Service_LED ---LED--- Mem(MB) Mem(MB) Available(%) 0 xxxxxxxxxx-0 OK Yes Yes Off GreenBlnk 16384 16384 100 1 xxxxxxxxxx-1 OK No Yes Off GreenBlnk 16384 16384 100 3par cli% admithw Checking nodes... Checking volumes... Checking system LDs... Checking ports... Checking SAS HBA firmware... Checking 4 SAS Port(s) for firmware upgrades Checking state of disks... Checking for drive table upgrade packages Checking cabling... Checking if this is an upgrade that added new drive types... Checking for disks to admit... Admitting PDs: this step can take an extended period of time 0 disks admitted Checking admin volume... Admin volume exists Checking cage firmware... Checking if logging LDs need to be created... System has fewer cages than nodes Using -ha mag for logging LDs No new logging LDs need to be created Checking if preserved data LDs need to be created... System has fewer cages than nodes; using -ha mag for preserved data LDs No new preserved LDs need to be created Checking if system scheduled tasks need to be created... Checking if the rights assigned to extended roles need to be updated... create role created basic_edit role created 3PAR_AO role created 3PAR_RM role created audit role created co role created security_admin role created Checking spares... Rebalancing and adding FC spares FC spare chunklets rebalanced; increased by 0 for a total of 3350 Rebalancing and adding NL spares No NL PDs present Rebalancing and adding SSD spares SSD spare chunklets rebalanced; increased by 0 for a total of 3574 Checking default CPGs... Checking srdata volume... System Reporter volume exists Checking default AO configuration... Checking fibre channel ports configuration... Checking system health... Checking alert Checking ao Checking cabling Checking cage Checking cert Checking dar Checking date Checking file Checking fs Checking host Checking ld Checking license Checking network Checking node Checking pd Checking pdch Checking port Checking qos Checking rc Checking snmp Checking task Checking vlun Checking vv Checking sp No issues reported. admithw has completed 3par cli% showport 0:1:2 N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState 0:1:2 initiator loss_sync 50002ACFF7023E62 50002AC012023E62 free SAS DP-2 - - ------------------------------------------------------------------------------------------------------- 1 3par cli% showport 1:1:2 N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState 1:1:2 initiator loss_sync 50002ACFF7023E62 50002AC112023E62 free SAS DP-2 - - ------------------------------------------------------------------------------------------------------- 1 3par cli% showport 1:1:1 N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState 1:1:1 initiator ready 50002ACFF7023E62 50002AC111023E62 disk SAS DP-1 - - --------------------------------------------------------------------------------------------------- 1 3par cli% showport 0:1:1 N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol Label Partner FailoverState 0:1:1 initiator ready 50002ACFF7023E62 50002AC011023E62 disk SAS DP-1 - - --------------------------------------------------------------------------------------------------- 1