cli% checkhealth -svc -detail Checking alert Checking ao Checking cabling Checking cage Checking dar Checking date Checking file Checking ld Checking host Checking license Checking network Checking node Checking pd Checking pdch Checking port Checking qos Checking rc Checking snmp Checking task Checking vlun Checking vv Checking sp Component -------------------Description------------------- Qty Alert New alerts 45 Cage Cages not on current firmware 3 Cage Degraded or failed cage power supplies 6 LD LDs with reduced availability 1 License Licenses which have expired 1 Network Errors detected on network 1 Node Power supplies which are failed or degraded 4 Node Power supplies with failed or degraded batteries 4 PD Magazines with failed servicemag operations 9 PD Magazines that are being serviced 5 PD Disks experiencing a high level of I/O per second 16 PD PDs that are failed 14 PD PDs that are degraded 3 QoS Unable to check QoS 1 Component ------------Identifier------------ ----------------------------------- --------------------------------------------------------------Description------- -------------------------------------------------------------------------------- ---------- Alert sw_task:3918 Task 3918 (type 'background_command ', name 'upgradecage') has failed (Task Failed). Please see task status for deta ils. Alert sw_task:16608 Task 16608 (type 'background_comman d', name 'upgradepd') has failed (Task Failed). Please see task status for detai ls. Alert sw_task:16609 Task 16609 (type 'background_comman d', name 'upgradepd') has failed (Task Failed). Please see task status for detai ls. Alert sw_task:16610 Task 16610 (type 'background_comman d', name 'upgradepd') has failed (Task Failed). Please see task status for detai ls. Alert sw_task:18723 Task 18723 (type 'system_task', nam e 'check_slow_disk') has failed (Marking task 18723 failed due to node down-). P lease see task status for details. Alert sw_cli Slow disk 2 found, but not marking it failed since the number of failed/degraded in the system (6) is higher than t he slow drive limit (2) Alert sw_os An Update is Available Alert sw_task:6878 Task 6878 (type 'check_vv', name 'c heckvv') has failed (Failed checkvv process-). Please see task status for d etails. Alert sw_task:25844 Task 25844 (type 'background_comman d', name 'tuneld') has failed (Task Failed). Please see task status for details. Alert sw_task:25845 Task 25845 (type 'background_comman d', name 'tuneld') has failed (Task Failed). Please see task status for details. Alert sw_task:18020 Task 18020 (type 'background_comman d', name 'upgradepd') has failed (Task Failed). Please see task status for detai ls. Alert sw_pdscrub:0 Media error fix on pd 55 ch 1172 fa iled-Create LD media-fail.55.1172 failed: Chunk 0 (55:1172) - chunk not cleaned yet Alert sw_cage_sled:1:23:0,sw_pd:59 Magazine 1:23:0, Physical Disk 59 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert sw_cage_sled:1:22:0,sw_pd:58 Magazine 1:22:0, Physical Disk 58 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert hw_cage:0,hw_cage_ps:0 Cage 0, Power Supply 0 Failed (Powe r Supply Unsupported {0x400}) Alert sw_system System write cache availability is degraded. Alert hw_cage:0,hw_cage_bat:0 Cage 0, Cage Battery 0 Failed (Cage Battery Not Present {0x5}) Alert hw_cage:0,hw_cage_bat:1 Cage 0, Cage Battery 1 Failed (Cage Battery Not Present {0x5}) Alert hw_cage:0,hw_cage_ifc:0 Cage 0, Interface Card 0 Failed (In terface Card Firmware Unknown {0x0}) Alert hw_cage:0,hw_cage_ifc:1 Cage 0, Interface Card 1 Failed (In terface Card Firmware Unknown {0x0}) Alert sw_cage_sled:1:19:0,sw_pd:57 Magazine 1:19:0, Physical Disk 57 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert sw_cage_sled:1:18:0,sw_pd:56 Magazine 1:18:0, Physical Disk 56 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert hw_cage:1,hw_cage_ps:1 Cage 1, Power Supply 1 Failed (Powe r Supply Unsupported {0x400}) Alert sw_cage_sled:1:14:0,sw_pd:54 Magazine 1:14:0, Physical Disk 54 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert hw_cage:2,hw_cage_ps:0 Cage 2, Power Supply 0 Failed (Powe r Supply Unsupported {0x400}) Alert hw_cage:2,hw_cage_ps:1 Cage 2, Power Supply 1 Failed (Powe r Supply Unsupported {0x400}) Alert hw_cage:2,hw_cage_ifc:0 Cage 2, Interface Card 0 Failed (In terface Card Firmware Unknown {0x0}) Alert hw_cage:2,hw_cage_ifc:1 Cage 2, Interface Card 1 Failed (In terface Card Firmware Unknown {0x0}) Alert sw_cage_sled:1:11:0,sw_pd:53 Magazine 1:11:0, Physical Disk 53 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert sw_cage_sled:1:10:0,sw_pd:52 Magazine 1:10:0, Physical Disk 52 F ailed (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa 1}, Servicing {0x12}) Alert sw_cage_sled:0:22:0,sw_pd:46 Magazine 0:22:0, Physical Disk 46 F ailed (Vacated {0x45}, Missing {0x81}, Disabled A Port {0x8d}, Disabled B Port { 0x91}, Invalid Media {0x98}, No Valid Ports {0xa1}, Servicing {0x12}) Alert sw_cage_sled:0:20:0,sw_pd:44 Magazine 0:20:0, Physical Disk 44 F ailed (Vacated {0x45}, Missing {0x81}, Disabled A Port {0x8d}, Disabled B Port { 0x91}, Invalid Media {0x98}, No Valid Ports {0xa1}, Servicing {0x12}) Alert sw_cage_sled:2:8:0,sw_pd:32 Magazine 2:8:0, Physical Disk 32 Fa iled (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa1 }, Servicing {0x12}) Alert sw_cage_sled:1:1:0,sw_pd:13 Magazine 1:1:0, Physical Disk 13 Fa iled (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa1 }, Servicing {0x12}) Alert sw_cage_sled:0:2:0,sw_pd:2 Magazine 0:2:0, Physical Disk 2 Fai led (Vacated {0x45}, Missing {0x81}, Invalid Media {0x98}, No Valid Ports {0xa1} , Servicing {0x12}) Alert sw_cage_sled:2:7:0,sw_pd:31 Magazine 2:7:0, Physical Disk 31 Fa iled (Vacated {0x45}, Invalid Media {0x98}, Servicing {0x12}) Alert sw_cage_sled:2:1:0,sw_pd:25 Magazine 2:1:0, Physical Disk 25 Fa iled (Vacated {0x45}, Invalid Media {0x98}, Servicing {0x12}) Alert hw_cage:1,hw_cage_ifc:0 Cage 1, Interface Card 0 Failed (In terface Card Firmware Unknown {0x0}) Alert hw_cage:1,hw_cage_ifc:1 Cage 1, Interface Card 1 Failed (In terface Card Firmware Unknown {0x0}) Alert sw_pd At least one drive (PD) in the syst em has an above normal temperature. Alert hw_cage:0,hw_cage_ps:1 Cage 0, Power Supply 1 Failed (Powe r Supply Unsupported {0x400}) Alert sw_cp:0:FC_r1 CPG 0 (FC_r1) could not grow with i ts normal grow parameters.-The following parameters were used: createald -wait 0 -cpsd FC_r1 -ssz 2 -ha mag -t r1 -p -devtype FC -n tp-0-sd-2 -sz 8192 Alert sw_sysmgr Total FC raw space usage at 13449G (above 95% of total 14144G) Alert sw_cp:4:FC_r5 CPG 4 (FC_r5) could not grow with i ts normal grow parameters.-The following parameters were used: createald -wait 0 -cpsd FC_r5 -t r5 -ha mag -ssz 5 -ss 32 -ch first -p -devtype FC -n tp-4-sd-1 -sz 8192 Alert sw_vv:8:DataStore_ESX_SAP_BDD_FCR1 Thin provisioned VV DataStore_ESX_S AP_BDD_FCR1 has reached reserved allocation warning of 480G (80% of 600G) Cage cage:0 Firmware is not current Cage cage:0 Power supply 0 is Unsupported Cage cage:0 Power supply 1 is Unsupported Cage cage:1 Firmware is not current Cage cage:1 Power supply 0 is Unsupported Cage cage:1 Power supply 1 is Unsupported Cage cage:2 Firmware is not current Cage cage:2 Power supply 0 is Unsupported Cage cage:2 Power supply 1 is Unsupported LD ld:tp-0-sd-1.0 LD has reduced availability. Curre nt: mag, Configured: cage License Peer Motion License has expired Network Node1:Admin Errors detected on network Node node:0 Power supply 0 detailed state is O scillating AC Failure Node node:0 Power supply 0 battery is NotPresen t Node node:0 Power supply 1 detailed state is O scillating AC Failure Node node:0 Power supply 1 battery is NotPresen t Node node:1 Power supply 0 detailed state is O scillating AC Failure Node node:1 Power supply 0 battery is NotPresen t Node node:1 Power supply 1 detailed state is O scillating AC Failure Node node:1 Power supply 1 battery is NotPresen t PD cage:0,mag:20 Magazine has a failed servicemag op eration PD cage:0,mag:22 Magazine is being serviced PD cage:1,mag:1 Magazine has a failed servicemag op eration PD cage:1,mag:10 Magazine has a failed servicemag op eration PD cage:1,mag:11 Magazine is being serviced PD cage:1,mag:13 Magazine is being serviced PD cage:1,mag:14 Magazine has a failed servicemag op eration PD cage:1,mag:18 Magazine has a failed servicemag op eration PD cage:1,mag:19 Magazine has a failed servicemag op eration PD cage:1,mag:22 Magazine has a failed servicemag op eration PD cage:1,mag:23 Magazine has a failed servicemag op eration PD cage:2,mag:1 Magazine is being serviced PD cage:2,mag:7 Magazine is being serviced PD cage:2,mag:8 Magazine has a failed servicemag op eration PD disk:12 Disk is experiencing a high level o f I/O per second: 141.0 PD disk:13 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:14 Disk is experiencing a high level o f I/O per second: 137.0 PD disk:15 Disk is experiencing a high level o f I/O per second: 94.4 PD disk:16 Disk is experiencing a high level o f I/O per second: 111.6 PD disk:17 Disk is experiencing a high level o f I/O per second: 137.2 PD disk:18 Disk is experiencing a high level o f I/O per second: 123.8 PD disk:19 Disk is experiencing a high level o f I/O per second: 77.6 PD disk:2 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:20 Disk is experiencing a high level o f I/O per second: 136.0 PD disk:21 Disk is experiencing a high level o f I/O per second: 131.2 PD disk:22 Disk is experiencing a high level o f I/O per second: 133.6 PD disk:23 Disk is experiencing a high level o f I/O per second: 197.2 PD disk:25 Failed States: vacated,invalid_medi a,servicing PD disk:31 Failed States: vacated,invalid_medi a,servicing PD disk:32 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:44 Failed States: vacated,missing,disa bled_A_port,disabled_B_port,invalid_media,no_valid_ports,servicing PD disk:46 Failed States: vacated,missing,disa bled_A_port,disabled_B_port,invalid_media,no_valid_ports,servicing PD disk:48 Disk is experiencing a high level o f I/O per second: 130.2 PD disk:50 Disk is experiencing a high level o f I/O per second: 126.6 PD disk:51 Disk is experiencing a high level o f I/O per second: 130.2 PD disk:52 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:53 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:54 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:55 Disk is experiencing a high level o f I/O per second: 130.0 PD disk:56 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:57 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:58 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:59 Failed States: vacated,missing,inva lid_media,no_valid_ports,servicing PD disk:72 Disk is experiencing a high level o f I/O per second: 137.6 PD disk:73 Degraded States: not_available_for_ allocations PD disk:76 Degraded States: not_available_for_ allocations PD disk:77 Degraded States: not_available_for_ allocations QoS -- Unable to check QoS - This system i s not licensed for System Reporter features